From Hentschel
(Created page with "== Basics == * getting nodes http://thomas:xxxxx@isy.home.hentschel.net/rest/nodes/ * get thermostat node http://thomas:xxxxx@isy.home.hentschel.net/rest/nodes/14%2023%20AC%20...") |
(No difference)
|
Revision as of 23:18, 14 December 2016
Basics
- getting nodes http://thomas:xxxxx@isy.home.hentschel.net/rest/nodes/
- get thermostat node http://thomas:xxxxx@isy.home.hentschel.net/rest/nodes/14%2023%20AC%201
- setting temp to 70F via REST http://thomas:xxxxx@isy.home.hentschel.net/rest/nodes/14%2023%20AC%201/set/CLISPH/140
Fan control off:
<node flag='0'> <address>14 23 AC 4</address> <name>Thermostat - Fan Control</name> ... <property id='ST' value='0' formatted='Off' uom='%/on/off'/> </node>
Fan control on
<node flag='0'> <address>14 23 AC 4</address> <name>Thermostat - Fan Control</name> ... <property id='ST' value='255' formatted='On' uom='%/on/off'/> </node>
Thermostat manuals
Design
- Use insteon 2450 to switch fireplace low-voltage control
- Control Insteon 2450 via Thermostat - Heat Control (insteon address: 14 23 AC 3) via ISY program
- Rewire house heater to use the 2nd stage heater control on the thermostat
- Sense fire place heater via 2450 input
- Engage house heater fan via ISY program